All Issue

2014 Vol.30, Issue 4 Preview Page
30 April 2014. pp. 93-99
Abstract
References
1
1.Brandl, H. (2006), “Energy foundations and other thermo-active ground structures”, Geotechnique, Vol.56, No.2, pp.81-122.
2
2.Gao, J., Zhang, X., Liu, J., Li, K., and Yang, J. (2008), “Numerical and experimental assessment of thermal performance of vertical energy piles: an application”, Applied Energy, Vol.85(10), pp.901-910.
3
3.Go, G. H., Yoon, S., Park, D. W., and Lee, S. R. (2013), “Thermal behavior of energy pile considering ground thermal conductivity and thermal interference between piles”, Journal of Korean Society of Civil Engineers, Vol.33, No.6, pp.2381-2391.
4
4.Johnston, I.W, Narsilio, G.A., and Colls, S. (2011), “Emerging geothermal energy technologies”, KSCE Journal of Civil Engineers, Vol.15(4), pp.643-653.
5
5.Jun, L., Xu, Z., Jun, G., and Jie, Y. (2009), “Evaluation of heat exchange rate of GHE in geothermal heat pump systems”, Renewable energy, Vol.34, pp.2898-2904.
6
6.Laloui, L., Nuth, M., and Vulliet, L. (2006), “Experimental and numerical investigations of the behavior of a heat exchanger pile”, International Journal for Numerical and Analytical Methods in Geomechanics, Vol.30, pp.763-781.
7
7.Lim, H. J., Kong, H. J., Kang, S. J., and Choi, J. H. (2011), “The effect of the installation condition of ground loop heat exchanger to the thermal conductivity and borehole resistance”, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.23, No.2, pp.95-102.
8
8.Lee, K. (2010), “Study on thermal characteristics of backfill materials for horizontal ground heat exchanger”, Master thesis, Korea University. 
9
9.Lee, C., Park, M., Min, S., Choi, H., and Sohn, B. (2010), “Evaluation of performance of grouts and pipe sections for closed-loop vertical ground heat exchanger by in-situ thermal response test”, Journal of Korean Geotechnical Society, Vol.26, No.7, pp.93-106. 
10
10.Pahud, D. and Matthey, B. (2001), “Comparison of the thermal performance of double U-pipe borehole heat exchangers measured in situ”, Energy and Building, Vol.33, pp.503-507.
11
11.Park, H. (2011), “Thermal conductivities of unsaturated Korean weathered granite soils”, Master thesis, KAIST.
12
12.Park, H., Park. H., Lee, S. R., and Go, G. H. (2012), “Estimation of thermal conductivity of weathered granite soils”, Journal of Korean Society of Civil Engineers, Vol.32, No.2C, pp.69-77.
13
13.Park, H. K., Lee, S. R., Yoon, S., and Choi, J. C. (2013), “Evaluation of thermal response and performance of PHC energy pile: Field experiments and numerical simulation”, Applied Energy, Vol.103, pp.12-24.
14
14.Park, S., Sohn, J. R., Park, Y. B., Ryu, H. K., and Choi, H. (2013), “Study on thermal behavior and design method for coil-type PHC energy pile”, Journal of Korean Geotechnical Society, Vol.29, No.8, pp.37-51..
15
15.Sohn, B. H., Shin. H. J., and Park, S. K. (2005), “Evaluation of effective thermal conductivity and thermal resistance in ground heat exchanger boreholes”, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.17, No.8, pp.695-703.
16
16.Yoon, S., Lee, S. R., Park, H. K., Park, D. W., and Go, G. H. (2013), “Prediction of heat exchange rate in PHC energy piles”, Journal of Korean Geotechnical Society, Vol.29, No.9, pp.31-41. 
17
17.Yoon, S., Lee, S. R., Go, G. H., Jianfeng, X., Park, H., and Park, D. (2014), “Thermal transfer behavior in two types of W-shaped ground heat exchangers installed in multilayer soils”, Geomechanics and Engineering, Vol.6, No.1, pp.79-98.
Information
  • Publisher :The Korean Geotechnical Society
  • Publisher(Ko) :한국지반공학회
  • Journal Title :Journal of the Korean Geotechnical Society
  • Journal Title(Ko) :한국지반공학회 논문집
  • Volume : 30
  • No :4
  • Pages :93-99
  • Received Date : 2014-03-12
  • Revised Date : 2014-04-01
  • Accepted Date : 2014-04-07