Abstract
References
3.Baek, S-K (2004), Study on ground-coupled heat pump system using hollow piles, Ph.D. Thesis, Busan University, Korea. 4.Brandl, H. (2006), “Energy foundation and other thermo-active ground structures”, Geotechnique, Vol.56, No.2, pp.81-122. 5.Carslaw, S. H. and Jaeger, J. C. (1959), Conduction of heat in solids, 2nd ed., Oxford Science Publication. 6.Cui, P., Li, X., Man, Y., and Fang, Z. (2011), “Heat transfer analysis of pile geothermal heat exchangers with spiral coils”, Applied Energy, Vol.88, No.11, pp.4113-4119. 7.Department Of Energy, DOE (2001), “Ground-source heat pumps applied to federal facilities-second edition”, Federal Energy Management Program, DOE/EE-0245(PNNL-13534), US Department of Energy 9.Environmental Protection Agency, EPA (1993), “Space Conditioning : The Next Frontier, Office of Air and Radiation”, 403-R-93-0044 (4/93), Energy Protection Agency, Washington D.C. 10.Gao, J., Zhang, X., Liu, J., Li, K., and Yang, J. (2008), “Numerical and experimental assessment of thermal performance of vertical energy piles”, An application, Applied Energy, Vol.85, pp.901-910. 11.Ingersoll, L. R., Zobel, O. J., and Ingersoll, A. C. (1954), Heat Conduction with engineering and geological application, McGraw- Hill, New York. 12.Jeong, S., Song, J., Min, H., and Lee, S. (2010), “Thermal influence factors of energy pile”, Journal of the Korean Society of Civil Engineers (KSCE), Vol.30, No.6C, pp.231-239. 13.Jun, L., Zhang, X., Gao, J., and Yang, J. (2009), “Evaluation of heat exchange rate of GHW in geothermal heat pump system”, Renewable Energy, Vol.34, pp.2898-2904. 14.Kavanaugh, S.P. and Rafferty, K. (1997), “Ground-Source Heat Pumps - Design of Geothermal Systems for Commercial and Institutional Buildings”, American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), Atlanta 15.Lee, C. (2012), Performance of ground heat exchangers for civil infrastructures, Ph.D. Thesis, Korea University, Korea. 16.Lee, C., Park, M., Min, S., Choi, H., and Sohn. B. (2010), “Evaluation of Performance of Grouts and Pipe sections for Close-Loop Vertical Ground Heat Exchanger by In-situ Thermal Response test”, Jounral of Korean Geotechnical Society (KGS), Vol.26, No.7, pp.93-106. 17.Man, L., Yang, H., Diao, N., Liu, J., and Fang, J. (2010), “A new model and analytical solutions for borehole and pile ground heat exchangers”, International Journal of Heat and Mass Transfer, Vol.53, pp.2593-2061. 18.Min, S., Park, S., Koh, H., Yoo, J., Jung, K., and Choi, H. (2012), “Study on equivalent heat exchange efficiency and design method for cast-in-place energy pile”, Proceedings of 2012 KGS Spring Conference, Korean Geotechnical Society (KGS), pp.655-666. 19.Nam, Y., Hwang, S., and Ooka, R. (2007), “Geothermal heat pump system using foundation pile structures”, Journal of Korea Society of Geothermal Energy Engineers, Vol.3, No.1, pp.51-60. 20.Nam, Y., Ooka, R., and Hwang, S. (2008), “Development of a numerical model to predict heat exchange rates for a ground source heat pump system”, Energy and Building, Vol.40, pp.2113-2140. 21.Nam, Y. and Ooka, R. (2011), “Development of potential map for ground and groundwater heat pump systems and the application to tokyo”, Energy and Building, Vol.43, pp.677-685. 22.Pahud, D. and Hubbuck, M. (2007), “Measured thermal performances of the energy pile system of the duck midfield as Zurick Airport”, Proceedings European Geothermal Congress 2007, Unterhaching, Germany, 30 May-1 June. 23.Park, Y-B, Park, J-B, and Lim, H-S (2007), “Construction method of ground heat exchanger using energy pile in ground source heat system”, KSCE magazine, Vol.55, No.7, pp.41-46. 24.Ryu, H-K (2008), “Development and performance evaluation of ground heat exchanger utilizing PHC pile foundation of building”, Journal of the Korean Solar Energy Society, Vol.28, No.5, pp.56-64. 25.Salomone, L. A. and Marlowe, J. I. (1989), “Soil and rock classification according to thermal conductivity : Design of ground- coupled heat pump systems : Final report”, Electric Power Research Inst.(EPRI), EPRI-CU-6482. 26.Sharqawy, M. H., Mokheimer, E. M., Habib, M. A., Badr, H. M., Said, N. A., and Al-Shayea, S. A. (2009), “Energy, energy and uncertainty analyses of the thermal response test for a ground heat exchanger”, International Journal of Energy Research, Vol.33, pp. 582-592. 27.Wagner, R. and Clauser, C. (2005), “Evaluating thermal response tests using parameter estimation for thermal conductivity and thermal capacity”, Journal of Geophysics and Engineering, Vol.2, pp.349-356.
Information
- Publisher :The Korean Geotechnical Society
- Publisher(Ko) :한국지반공학회
- Journal Title :Journal of the Korean Geotechnical Society
- Journal Title(Ko) :한국지반공학회 논문집
- Volume : 29
- No :8
- Pages :37-51
- Received Date : 2013-01-24
- Revised Date : 2013-07-25
- Accepted Date : 2013-07-30
- DOI :https://doi.org/10.7843/kgs.2013.29.8.37


Journal of the Korean Geotechnical Society







